Inspection of tank internal lining.

Inspection process of tank internal lining.

All personnel involved in the coating works should be qualified as per client recommendation.The environmental conditions shall be checked and if acceptable only the work shall commence.Clicks the below mentioned link and see all details. https://jittuqaqc.com/pqt-for-fiber-glass-lining-of-tank/

Prior to start of the internal lining of the tanks application ambient temperature,metal temperature,relative humidity etc.should be checked and recorded.

The plural component airless spray pump,hoses,nozzles and all fittings shall be checked for its condition and compatibility to the coating system.

Inspection of tank internal lining.
Plural Component Pump

The inspection of tank internal lining,The compressed air cleanliness shall be checked for cleanliness (oil & water traces) prior to start of blasting ensure that equipment is good working condition.

Ensure surface preparation complied with client specification and manufacturer’s recommendation.Only after third party and client approval for surface preparation after that primer coat shall be applied.

The inspection of tank internal lining,The primer coat inspection and approval shall be obtained.The primer coat minimum/maximum thickness shall be recorded and the DFT should be within the specified range.Only after obtaining client approval the lining work shall commence.

The inspection of tank internal lining,DFT checking should be carried out as per SSPC PA2,Holiday testing shall be as per NACE SP 0188,and curing test by rubbing an acetone on the resin as per client requirement prior to the application of gel coat.

The fiber glass lining shall be visually examined.The DFT check and 100% holiday test of the lining shall be checked prior to gel coat application.The test voltage shall be as per manufacturer’s recommendation.Final visual inspection shall be carried out for pinhole in gel coat and after irregularities and repair as per manufacturer’s recommendation.

The inspection of tank internal lining,Surface cleanliness of Sa 2.5 as per ISO 8501-1,surface profile check using a replica tape as per NACE RP 0287,dust test grade-2 as per ISO 8502-3,Chloride test not exceeding 5µg/cm² as per ISO 8502-6 & 9,and adhesion test carried out as per ASTM D4541.Clicks the below mentioned link and see all details.    https://jittuqaqc.com/surface-preparation-of-fiber-glass-lining-surface/

Inspection of tank internal lining.
Surface Profile Test
Inspection of tank internal lining.
Metal Temperature
Inspection of tank internal lining.
Dust Embedment Test
Inspection of tank internal lining.
Salt Test

The applied lined system shall be free from cracks,pinholes,shrinkage,scattered pockets and other defects.A layout diagram shall be prepared for the areas offered for inspection by the applicator and shall be duly signed by client inspector.

All testing and measuring equipment shall be with valid calibration and verified periodically while in use.

Adhesion test on the coated sample plate during the appication of the tank lining shall be carried out as per ASTM D4541 Potable adhesion tester.The same shall be carried out on a separate plate after immersing the sample plate in water (60°C) for 24 hours.

The Contractor shall have a technical representative from the lining manufacture,who should be present to assist and witness the application of each coating system without any additional cost and time impact to company.

All inspection shall be carried out as per work proceedure,inspection test plan and manufacturer’s recommendations.